# This is an example localConfig.py file
# Always include these lines at the top of your localConfig.py file.
from serverConfig import *
import serverConfig
# Adding a new database is fairly complicated. Multiple steps must be
# defined and done in the correct order.
# We want T, Td, rh, and maxrh in this database. Since rh and max rh are
# not defined in serverConfig, we add it in localConfig.py.
rh = ("RH", SCALAR, "%", "Relative Humidity", 100.0, 0.0, 0, NO)
maxrh = ("MaxRH", SCALAR, "%", "Maximum Relative Humidity", 100.0, 0.0, 0, NO)
# We want the maxRH to have a special time constraint that is not defined
# in serverConfig. The other elements use already defined configurations.
# This time constraint starts at 6am and is 4 hours long, repeats daily.
LT4gap = localTC(6*HOUR, 24*HOUR, 4*HOUR, 0)
# Now we define the database attributes. Our database is called Ag, is
# model-based (not singleton), and we only want 1 version of it.
Ag = ('Ag', GRID, '', NO, NO, 1, 0)
# Now we define the new parm groupings which relate weather elements to
# time constraints. The T and Td come from serverConfig.py. The T, Td, and
# rh get the basic 1 hourly time constraints.
AG_MODEL = [([Temp,Td,rh], TC1), ([maxrh], LT4gap)]
# Very important step so that server sees this new definition.
# There can only be ONE dbs line in the localConfig.py
dbs = [(Ag, AG_MODEL)]